Search By Rego No.
Matching Vehicle By Rego No.: | |
{{reg.VehicleLongDescription}} | Select |
Search By VIN
(Eg. VIN or Keywords ‘2002 Holden Commodore’)
Matching Vehicle By VIN/Keyword: | |
{{reg.VehicleLongDescription}} | Select |
Cars, 4WDs, Vans & Utes up to 4.5T GVM
Motorbikes, Scooters, ATVs, Mopeds & More
Trucks & Buses over 4.5T GVM
Tractors, Mowers, Machinery & Stationary Equipment
Select your vehicle details from the drop downs
XREF: {{prc.CrossRefName}} |
status: No Longer Available |
Interchangable With {{prc.ProductCode}} |
{{prc.WebDescription}} |
Manufacturer: {{prc.OemName}} |
Note: {{prc.Notes}} |
XREF: {{filter.OemProductCode1}} |
status: No Longer Available |
Interchangable With {{prc.ProductCode}} |
{{prc.WebDescription}} |
Manufacturer: {{prc.OemName}} |
Note: {{prc.Notes}} |
XREF: {{filter.OemProductCode2}} |
status: No Longer Available |
Interchangable With {{prc.ProductCode}} |
{{prc.WebDescription}} |
Manufacturer: {{prc.OemName}} |
Note: {{prc.Notes}} |
Enter your registration number and Australian State and instantly see all filters compatible with your vehicle.
Delivering the Ryco promise of ‘genuine performance’ requires a world-class laboratory and highly committed experts. Our specialist team of qualified engineers draws on over a century’s worth of combined experience. They work in Ryco’s custom-built automotive filtration laboratory, the only one of its kind in Australasia testing and validating our filters to ensure each achieves the outstanding level quality our customers deserve.
Our engineers carefully test all filters to ensure they meet or exceed the specifications of original product in the three critical areas of efficiency, life and flow. Filters are tested according to ISO and SAE international industry standards.
Our design philosophy is to meet or exceed original equipment
Full Flow Oil Filters
Diesel fuel and Petrol filters
Hydraulic filters
Aerosol separator (Crankcase)
Mechanical testing of oil and fuel filters
Air Filters
Utilizing Australasia’s only multi pass test machine to undertake a thorough assessment process that incorporates thorough diagnostic testing
Multi-pass testing uses a specified contaminant, of known sizes, added regularly in measured quantities to the fluid, which is pumped continuously through the filter.
Measured samples of fluid are then taken at timed intervals from the upstream and downstream bsides of the filter.
The contaminant in the samples is measured for particle sizes and quantities of each size, or a range of sizes. These are accurately measured using particle counters.
From the upstream and downstream measurements, a Beta ratio is formulated by dividing the number of particles of a particular size in the upstream flow by the number of particles of the same size in the downstream flow.